Tripp Lite 2–2.4kW Single-Phase ATS/Switched PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount

Tripp Lite 2–2.4kW Single-Phase ATS/Switched PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount, Monitored,Switched, 1U, Horizontal, Black, 10 AC outlet(s), C13 coupler

* Images are for illustrative purposes only.

£882.22 £735.18 Ex. VAT

Out of stock

Finance/leasing available for orders over £1000 Inc VAT

Free mainland UK shipping on orders over £150 Ex VAT

The PDUMH15HVATNET 2–2.4kW Single-Phase 200–240V ATS/Switched PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features eight switched and two unswitched C13 outlets. Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVATNET constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably discovered. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs. Connecting the optional ENVIROSENSE module (sold separately) lets you remotely monitor temperature and humidity. nnPrimary and Secondary Inputs for Power Redundancy n● Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations n● Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources n● 8 switched and 2 unswitched C13 outlets nnAutomatic Transfer Switching n● Dynamic solid-state (TRIAC) automatic transfer switching n● Switches to secondary power source if primary source fails or becomes unstable n● 2–5 ms transfer time ensures uninterrupted operation of connected equipment n● Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source nnDigital Load Meter n● Easy-to-read ammeter displays total current used by connected equipment nnLED Indicators n● Individual LEDs display outlet on/off status and input power status on primary and secondary inputs nnAdvanced Network Monitoring n● Built-in Ethernet network interface allows remote access for power monitoring, configuration, control and notification via web browser, SSH, telnet or SNMP n● Optional ENVIROSENSE module (sold separately) monitors temperature and humidity nnBroad Communications Compatibility n● Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP protocols Mounts Horizontally in 1U of Rack Space n● Compatible with EIA-standard 19 in. racksn● Single-phase IEC-320 C14 input n● 8 switched and 2 unswitched C13 outlets n● Automatic transfer switching within 2–5 ms n● Ethernet network interface for remote outlet control n● Digital load meter for real-time output current monitoringnnPackage Includesnn● PDUMH15HVATNET TAA-Compliant 2–2.4kW Single-Phase ATS/Switched PDU n● (10) C14 plug lock inserts n● (2) C13 to C14 power cords, 3.6 m (11.8 ft.) n● SNMPWEBCARD configuration cable n● (2) Mounting brackets, horizontal n● (2) Mounting brackets, vertical n● (6) Screws n● Owner’s manual


Product ID: PDUMH15HVATNET

Model: 2–2.4kW Single-Phase ATS/Switched PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount

Datasheet: http://objects.icecat.biz/objects/mmo_33588967_1487586905_2113_5253.pdf

Brand

EAN

37332197504

Reviews

There are no reviews yet.

Be the first to review “Tripp Lite 2–2.4kW Single-Phase ATS/Switched PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount”

Before you go...

Before you leave, here is £5 towards your next order over £150 Ex VAT! Just click the button below to apply the coupon...