Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
LED status indicators
Quickly understand unit and power status with visual indicators.
Feature | Feature Value |
---|---|
UPS topology | Line-Interactive |
Output power capacity | 500 VA |
Output power | 300 W |
Waveform | Sine |
Input operation voltage (min) | 160 V |
Input operation voltage (max) | 280 V |
Input frequency | 45/65 Hz |
Output frequency regulation | 50 Hz |
Automatic Voltage Regulation (AVR) | Y |
Maximum current | 2 A |
Surge energy rating | 273 J |
Hold time (min) | 6 ms |
Hold time (max) | 10 ms |
Efficiency | 98.7% |
Noise level | 45 dB |
Surge protection | Y |
Audible alarm(s) | Y |
Audible alarm modes | Low battery alarm,Overload alarm |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
AC outlets quantity | 3 AC outlet(s) |
Number of output IEC jumpers | 1 |
Battery technology | Sealed Lead Acid (VRLA) |
Battery capacity | 7.2 Ah |
Battery capacity | 47 VAh |
Battery voltage | 12 V |
Typical backup time at full load | 1.3 min |
Typical backup time at half load | 7.6 min |
Automatic battery test | Y |
Form factor | Tower |
Product colour | Black |
Cable length | 1.83 m |
LED indicators | Battery replacement |
Energy Star certified | Y |
RoHS compliance | Y |
Certification | CE, REACH, PEP, EOLI |
Operating temperature (T-T) | 0 – 40 °C |
Storage temperature (T-T) | -15 – 45 °C |
Operating relative humidity (H-H) | 0 – 95% |
Storage relative humidity (H-H) | 0 – 95% |
Operating altitude | 0 – 3000 m |
Non-operating altitude | 0 – 15000 m |
Width | 115 mm |
Depth | 213 mm |
Height | 185 mm |
Weight | 5.2 kg |
Manual | Y |
Package width | 190 mm |
Package depth | 291 mm |
Package height | 257 mm |
Package weight | 5.68 kg |
Quantity per pallet | 60 pc(s) |
Quantity per master (outer) case | 2 pc(s) |
Nominal output voltage | 230 V |
Nominal input voltage | 230 V |